About UsServicesProductsSupportNewsContact Us
Home <
Careers <
Links <
Site Map <



Use this quick online form to request further details.
Privacy Statement <
 
Products > Tensile stages for XRD
MICROTEST three point bending and tensile/compression modules have been specifically designed to observe the high stress region of the sample with SEM or XRD systems. Windows software sets drive parameters and displays the stress/strain curve live on the PC screen. Loadcells from 2N to 5KN cover most applications, with extension rates from 0.02mm/min to 50mm/min. Special versions can be manufactured to customers requirements. All modules are controlled from Microtest tensile testing software.
 Tensile stages for XRD, transmitted & reflected beam

Two different types of stages are available for XRD applications, those that allow reflected beam only and those that allow reflected and transmitted beam.

The standard Deben tensile stages, 200N, 2KN and 5KN which are available for SEM and optical microscopy can also be fitted to XRD machines, but because these are compact testing stages with only one central leadscrew they are only suitable for reflected XRD not transmitted. The advantage of these stages is that they are cost effective and relatively small and light. See the 200N stage shown top right as an example of a reflected only stage. Typical incident and reflected angles for these stages are +/-60-70.

For reflected and transmitted applications you need a void behind the specimen which requires a dual leadscrew solution. The Deben 2KN dual leadscrew stage is very versitile, for XRD applications it would normally be mounted horizontally allowing incident and take off angles up to +/-70. The jaws can easily be exchanged allowing customised jaws to be fitted. Optionally the system can be supplied with heating only or heating/cooling jaws with temperature range from room temperature to 550C or from -150C to 550C. An example of the 2KN dual leadscrew stage (with fibre jaws) is shown bottom right.

The 2KN dual leadscrew stage is ideal for Synchrotron as well as optical microscopy and XRD applications.

200N tensile stage (reflected) fitted to Bruker D8 X-Ray Diffractometer. Picture courtesy of Research Center Caesar, Bonn
2KN dual leadscrew stage for transmitted & reflected XRD & synchrotron applications
   
    The content of this website (content being images, text, sound and video files, programs and scripts) of this website is copyright Deben UK Limited unless specifically mentioned. All rights expressly reserved. For our full copyright policy see privacy statement.
Site design: By The Scruff